RE: [SPAM] Re: Column to Column via End Plate
[Subject Prev][Subject Next][Thread Prev][Thread Next]- To: <seaint(--nospam--at)seaint.org>
- Subject: RE: [SPAM] Re: Column to Column via End Plate
- From: "David Maynard" <DMaynard(--nospam--at)kfx.com>
- Date: Tue, 30 May 2006 14:35:49 -0600
Gary, Thanks for the response. I won't be able to sub the W12 with the W14. My KL/r exceeds 200 with this. *snaps fingers* Otherwise, I was totally going that rout. Dave -----Original Message----- From: Gary Hodgson & Associates [mailto:ghodgson(--nospam--at)bellnet.ca] Sent: Saturday, May 13, 2006 6:46 AM To: seaint(--nospam--at)seaint.org Subject: [SPAM] Re: Column to Column via End Plate David, I have seen a recommended detail for such a connection as I had a similar problem. However my memory fails me and I can't recall where I saw it, There were no specific recommendations for designing it. I do have a detail for such a splice where there is a need to transfer moment and you are welcome to it. I gather from what you have described that the webs are aligned, in which case it should be ok to use a single cap plate on the existing column. I think Bill's warning is appropriate to plates with large moments, but I think for a plate largely subject to through compression and some shear, it should be ok. I would still advise you to check any thick plates for laminations. I would make sure that any uplift on the plate is also checked. Finally, I wonder if you could substitute a W14x53 as the interior dimensions of the two cols would then align Gary P 905-357-6406, F 905-357-4852 On 12 May 2006 at 12:15, David Maynard wrote: > This is the scenario. > > Existing structure with W14x120 Corner Columns. There is a beam that connects all of the columns at their top. > > A new structure will be built above the existing structure. The corner column of the existing structure are in line with that of the new structure (common center line). New corner columns are W12x53. > > The base of the new column is a shear connection to that of the old one. > > My solution is to weld a cap plate to the existing column. The new corner column will weld to that cap plate. > > My question is: > What should I use for a design thickness of this steel plate??? I can't seem to find the provisions for this anywhere, but maybe I'm not looking hard enough. I'd appreciate some help. > > Sincerely, > Dave Maynard, PE > Gillette, Wyoming > > -- > No virus found in this outgoing message. > Checked by AVG Free Edition. > Version: 7.1.392 / Virus Database: 268.5.6/337 - Release Date: 5/11/2006 > > > ******* ****** ******* ******** ******* ******* ******* *** > * Read list FAQ at: http://www.seaint.org/list_FAQ.asp > * > * This email was sent to you via Structural Engineers > * Association of Southern California (SEAOSC) server. To > * subscribe (no fee) or UnSubscribe, please go to: > * > * http://www.seaint.org/sealist1.asp > * > * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you > * send to the list is public domain and may be re-posted > * without your permission. Make sure you visit our web > * site at: http://www.seaint.org > ******* ****** ****** ****** ******* ****** ****** ******** ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ******** -- No virus found in this incoming message. Checked by AVG Free Edition. Version: 7.1.392 / Virus Database: 268.5.6/339 - Release Date: 5/14/2006 -- No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.1.394 / Virus Database: 268.7.4/351 - Release Date: 5/29/2006 ******* ****** ******* ******** ******* ******* ******* *** * Read list FAQ at: http://www.seaint.org/list_FAQ.asp * * This email was sent to you via Structural Engineers * Association of Southern California (SEAOSC) server. To * subscribe (no fee) or UnSubscribe, please go to: * * http://www.seaint.org/sealist1.asp * * Questions to seaint-ad(--nospam--at)seaint.org. Remember, any email you * send to the list is public domain and may be re-posted * without your permission. Make sure you visit our web * site at: http://www.seaint.org ******* ****** ****** ****** ******* ****** ****** ********
- Follow-Ups:
- RE: [SPAM] Re: Column to Column via End Plate
- From: Bill Allen
- RE: [SPAM] Re: Column to Column via End Plate
- Prev by Subject: [Fwd: Help! -- structural engineers needed to save NOLA buildings]
- Next by Subject: RE: [SPAM] Re: Column to Column via End Plate
- Previous by thread: FW: "Decoration Day" [WAS: Lag screws...]
- Next by thread: RE: [SPAM] Re: Column to Column via End Plate
- About this archive
- Messages sorted by: [Subject][Thread][Author][Date]